Rebar Corrosion Detector TC600

TC600 rebar corrosion detector is designed for assessing the corrosion of the reinforced concrete structure and components by half-cell potential method, the electrode is passed over the surface of the concrete and the potential voltage difference is recorded, then the corrosion of rebar is assessed.

Features

● Non-destructive testing the corrosion in rebar.

● Detection of the corrosion condition of the rebar accurately and conveniently by field potential measurement.

● Possibility to store, view, delete data and transfer all readings to PC with USB interface and serial port.

● Faster and more accurate processing of data, presentation of test area and reading as numbers or graphics.

● Display of measurement values in 9 grey-scale or colorful graphics.

● Permanent copper/copper sulphate reference electrodes to measure electrical potentials.

Standard Delivery
Main unit 1
Electrode 2
Signal cable 2
USB connecting cable 1
RS232 connecting cable 1
Connecting bar 1
Extension cable 1
Clamp 1
Hygrothermograph 1
Measuring tape 1
AA battery (LR6) 6
Shoulder strap 1
Instruction manual 1
TIME certificate 1
Warranty card 1

 

Technical Specification
Measuring method Potential measurement
Measuring range ±1000mv
Resolution 1mv
Memory Mass storage
Space between testing points 1~100cm adjustable
Interface RS232 and USB
Power supply AA batteries (LR6)×6
Operating temperature -10℃~+40℃
Relative humidity <90%RH
Dimensions Main unit 210mm×153mm×90mm
Probe Φ30mm×120mm
Weight Main unit 880g
Probe 100g